{"id":152,"date":"2021-12-29T14:43:41","date_gmt":"2021-12-29T13:43:41","guid":{"rendered":"https:\/\/jpehm.org\/?p=152"},"modified":"2022-01-18T14:44:30","modified_gmt":"2022-01-18T13:44:30","slug":"fiabilidad-del-dispositivo-cw-nirs-humon-beta-para-la-medicion-de-saturacion-de-oxigeno-muscular-durante-el-esqui-alpino-un-estudio-piloto","status":"publish","type":"post","link":"https:\/\/jpehm.org\/index.php\/2021\/12\/29\/fiabilidad-del-dispositivo-cw-nirs-humon-beta-para-la-medicion-de-saturacion-de-oxigeno-muscular-durante-el-esqui-alpino-un-estudio-piloto\/","title":{"rendered":"Fiabilidad del dispositivo CW-NIRS humon beta para la medici\u00f3n de saturaci\u00f3n de ox\u00edgeno muscular durante el esqu\u00ed alpino: un estudio piloto"},"content":{"rendered":"<section class=\"article-main\">\n<div class=\"date-details-appears\">Vol. 3 N\u00fam. 2 (2021): Journal of physical education and human movement, Art\u00edculos, P\u00e1ginas 7-16<\/div>\n<div class=\"article-doi\"><strong>DOI:<\/strong>\u00a0<a href=\"https:\/\/doi.org\/10.24310\/JPEHMjpehmjpehm.v3i213035\">https:\/\/doi.org\/10.24310\/JPEHMjpehmjpehm.v3i213035<\/a><\/div>\n<div class=\"article-controls\"><a data-toggle=\"modal\" data-target=\"#modal-copyright\">\u00a0Derechos de autor<\/a>\u00a0<a data-toggle=\"modal\" data-target=\"#modal-citation\">\u00a0C\u00f3mo citar<\/a><\/div>\n<div id=\"summary\" class=\"article-summary\">\n<h3>Resumen<\/h3>\n<div class=\"article-abstract\">\n<p>El siguiente estudio analiz\u00f3 la fiabilidad de un nuevo dispositivo (Humon Beta, Dynometrics, Inc. Boston), de onda continua (continuous wave, CW), evaluando la Sm02 del vasto lateral dominante durante cuatro estadios (basal, calentamiento, ejercicio, recuperaci\u00f3n) a trav\u00e9s de un protocolo de esqu\u00ed alpino en simulador. Trece participantes sanos fueron evaluados mediante un dise\u00f1o de medidas repetidas (test re-test) con 48 horas de separaci\u00f3n entre pruebas. Los resultados muestran tendencia a la fiabilidad, absoluta y relativa para las medidas de Sm02 pico y media durante los cuatro estadios (CV: 5,14 \u2013 12,90; ICC: 0,40 \u2013 0,87). La SmO2 es un condicionante limitador del rendimiento, por consiguiente, su posible modificaci\u00f3n mediante el entrenamiento ser\u00eda beneficiosa para el desarrollo de esta pr\u00e1ctica deportiva. El dispositivo CW-NIRS puede ser una herramienta fiable para monitorizar los cambios de la SmO2, en diferentes estadios para los esquiadores de esqu\u00ed alpino, dando informaci\u00f3n fisiol\u00f3gica relevante para la pr\u00e1ctica.<\/p>\n<\/div>\n<\/div>\n<div id=\"keywords\" class=\"article-keywords\">\n<h3>Palabras clave:<\/h3>\n<div class=\"\"><span class=\"value\">SmO2, iMUDS, espectroscopia de infrarrojo cercano, simulador de esqu\u00ed<\/span><\/div>\n<\/div>\n<div id=\"citedby\" class=\"article-citedby\">\n<h3>Citado por<\/h3>\n<div class=\"item citations-container\" data-image-path=\"https:\/\/revistas.uma.es\/plugins\/generic\/citations\/images\/\" data-citations-url=\"https:\/\/revistas.uma.es\/index.php\/JPEHM\/citations\/get?citationsId=10.24310%2FJPEHMjpehmjpehm.v3i213035&amp;citationsShowList=1&amp;citationsProvider=all\" data-citations-provider=\"all\" data-citations-total=\"1\" data-citations-list=\"1\" data-show-google=\"1\" data-show-pmc=\"0\">\n<div class=\"citations-count\">\n<div class=\"citations-count-google\"><a href=\"https:\/\/scholar.google.com\/scholar?q=10.24310\/JPEHMjpehmjpehm.v3i213035\" target=\"_blank\" rel=\"noopener noreferrer\"><img decoding=\"async\" src=\"https:\/\/revistas.uma.es\/plugins\/generic\/citations\/images\/scholar.png\" alt=\"Google Scholar\" \/><\/a><\/div>\n<\/div>\n<div class=\"citations-list\"><\/div>\n<\/div>\n<\/div>\n<\/section>\n<section class=\"article-more-details\">\n<h3 class=\"sr-only\">Detalles del art\u00edculo<\/h3>\n<div class=\"article-references\">\n<h3>Referencias<\/h3>\n<div class=\"article-references-content\">\n<p>Cohen, G., Gull, E., Reichman, D. R., Millis, A. J., &amp; Rabani, E. (2013). Numerically exact long-time magnetization dynamics at the nonequilibrium Kondo crossover of the Anderson impurity model. Physical Review B &#8211; Condensed Matter and Materials Physics, 87(19).\u00a0<a href=\"https:\/\/doi.org\/10.1103\/PhysRevB.87.195108\">https:\/\/doi.org\/10.1103\/PhysRevB.87.195108<\/a><\/p>\n<p>Contreras-Brice\u00f1o, F., Espinosa-Ramirez, M., Hevia, G., Llambias, D., Carrasco, M., Cerda, F., L\u00f3pez-Fuenzalida, A., Garc\u00eda, P., Gabrielli, L., &amp; Viscor, G. (2019). Reliability of NIRS portable device for measuring intercostal muscles oxygenation during exercise. Journal of Sports Sciences, 37(23), 2653\u20132659.\u00a0<a href=\"https:\/\/doi.org\/10.1080\/02640414.2019.1653422\">https:\/\/doi.org\/10.1080\/02640414.2019.1653422<\/a><\/p>\n<p>Crum, E. M., O\u2019connor, W. J., Van Loo, L., Valckx, M., &amp; Stannard, S. R. (2017). Validity and reliability of the Moxy oxygen monitor during incremental cycling exercise. European Journal of Sport Science, 17(8), 1037\u20131043.\u00a0<a href=\"https:\/\/doi.org\/10.1080\/17461391.2017.1330899\">https:\/\/doi.org\/10.1080\/17461391.2017.1330899<\/a><\/p>\n<p>Farzam, P., Starkweather, Z., &amp; Franceschini, M. A. (2018). Validation of a novel wearable, wireless technology to estimate oxygen levels and lactate threshold power in the exercising muscle. Physiological Reports, 6(7), 1\u201314.\u00a0<a href=\"https:\/\/doi.org\/10.14814\/phy2.13664\">https:\/\/doi.org\/10.14814\/phy2.13664<\/a><\/p>\n<p>Feldmann, A., Schmitz, R., &amp; Erlacher, D. (2019). Near-infrared spectroscopy-derived muscle oxygen saturation on a 0% to 100% scale: reliability and validity of the Moxy Monitor. Journal of Biomedical Optics, 24(11), 1.\u00a0<a href=\"https:\/\/doi.org\/10.1117\/1.jbo.24.11.115001\">https:\/\/doi.org\/10.1117\/1.jbo.24.11.115001<\/a><\/p>\n<p>Ferguson, R. A. (2010). Limitations to performance during alpine skiing. Experimental Physiology, 95(3), 404\u2013410.\u00a0<a href=\"https:\/\/doi.org\/10.1113\/expphysiol.2009.047563\">https:\/\/doi.org\/10.1113\/expphysiol.2009.047563<\/a><\/p>\n<p>Ferrari, M., Muthalib, M., &amp; Quaresima, V. (2011). The use of near-infrared spectroscopy in understanding skeletal muscle physiology: Recent developments. Philosophical Transactions of the Royal Society, 369(1955), 4577\u20134590.\u00a0<a href=\"https:\/\/doi.org\/10.1098\/rsta.2011.0230\">https:\/\/doi.org\/10.1098\/rsta.2011.0230<\/a><\/p>\n<p>Garcia-Ramos, A., &amp; Janicijevic, D. (2020). Potential benefits of multicenter reliability studies in sports science: A practical guide for its implementation. Isokinetics and Exercise Science, 28(2), 199\u2013204.\u00a0<a href=\"https:\/\/doi.org\/10.3233\/IES-192242\">https:\/\/doi.org\/10.3233\/IES-192242<\/a><\/p>\n<p>Hamaoka, T., McCully, K. K., Niwayama, M., &amp; Chance, B. (2011). The use of muscle near-infrared spectroscopy in sport, health and medical sciences: Recent developments. Philosophical Transactions of the Royal Society A: Mathematical, Physical and Engineering Sciences, 369(1955), 4591\u20134604.\u00a0<a href=\"https:\/\/doi.org\/10.1098\/rsta.2011.0298\">https:\/\/doi.org\/10.1098\/rsta.2011.0298<\/a><\/p>\n<p>Hopkins, W. G., Marshall, S. W., Batterham, A. M., &amp; Hanin, J. (2009). Progressive statistics for studies in sports medicine and exercise science. Medicine and Science in Sports and Exercise, 41(1), 3\u201312.\u00a0<a href=\"https:\/\/doi.org\/10.1249\/MSS.0b013e31818cb278\">https:\/\/doi.org\/10.1249\/MSS.0b013e31818cb278<\/a><\/p>\n<p>Liljequist, D., Elfving, B., &amp; Roaldsen, K. S. (2019). Intraclass correlation \u2013 A discussion and demonstration of basic features. In PLoS ONE (Vol. 14, Issue 7).\u00a0<a href=\"https:\/\/doi.org\/10.1371\/journal.pone.0219854\">https:\/\/doi.org\/10.1371\/journal.pone.0219854<\/a><\/p>\n<p>McCully, K. K., &amp; Hamaoka, T. (2000). Near_Infrared_Spectroscopy__What_Can_It_Tell_Us.6.pdf.\u00a0<a href=\"https:\/\/doi.org\/McCully\">https:\/\/doi.org\/McCully<\/a>,<\/p>\n<p>K. K., &amp; Hamaoka, T. (2000). Near-infrared spectroscopy: what can it tell us about oxygen saturation in skeletal muscle?. Exercise and sport sciences reviews, 28(3), 123-127.<\/p>\n<p>Neary, J. P. (2004). Application of near infrared spectroscopy to exercise sports science. Canadian journal of applied physiology, 29(4), 488-503.<\/p>\n<p>Quaresima, V., Lepanto, R., &amp; Ferrari, M. (2003). The use of near infrared spectroscopy in sports medicine. Journal of Sports Medicine and Physical Fitness, 43(1), 1\u201313.<\/p>\n<p>Romer, L. M., Lovering, A. T., Haverkamp, H. C., Pegelow, D. F., &amp; Dempsey, J. A. (2006). Effect of inspiratory muscle work on peripheral fatigue of locomotor muscles in healthy humans. Journal of Physiology, 571(2), 425\u2013439.\u00a0<a href=\"https:\/\/doi.org\/10.1113\/jphysiol.2005.099697\">https:\/\/doi.org\/10.1113\/jphysiol.2005.099697<\/a><\/p>\n<p>Seifert, J. G., Kipp, R. W., Amann, M., &amp; Gazal, O. (2005). Muscle damage, fluid ingestion, and energy supplementation during recreational alpine skiing. International Journal of Sport Nutrition and Exercise Metabolism, 15(5), 528\u2013536.\u00a0<a href=\"https:\/\/doi.org\/10.1123\/ijsnem.15.5.528\">https:\/\/doi.org\/10.1123\/ijsnem.15.5.528<\/a><\/p>\n<p>Sirio, L. (2017). Confiabilidad de par\u00e1metros fisiol\u00f3gicos estimados por elementos vestibles (wearables). Ritmo card\u00edaco, posici\u00f3n y aceleraci\u00f3n, ECG. 5 . XVI Seminario de Ingenier\u00eda Biom\u00e9dica, Universidad de la Rep\u00fablica, Uruguay.<\/p>\n<p>Szmedra, L., Im, J., Nioka, S., Chance, B., &amp; Rundell, K. W. (2001). Hemoglobin\/myoglobin oxygen desaturation during Alpine skiing. Medicine and Science in Sports and Exercise, 33(2), 232\u2013236.\u00a0<a href=\"https:\/\/doi.org\/10.1097\/00005768-200102000-00010\">https:\/\/doi.org\/10.1097\/00005768-200102000-00010<\/a><\/p>\n<p>Thiel, C., Vogt, L., Himmelreich, H., H\u00fcbscher, M., &amp; Banzer, W. (2011). Reproducibility of muscle oxygen saturation. International Journal of Sports Medicine, 32(4), 277\u2013280.\u00a0<a href=\"https:\/\/doi.org\/10.1055\/s-0030-1269922\">https:\/\/doi.org\/10.1055\/s-0030-1269922<\/a><\/p>\n<p>Turner, L. A., Tecklenburg-Lund, S., Chapman, R. F., Stager, J. M., Duke, J. W., &amp; Mickleborough, T. D. (2013). Inspiratory loading and limb locomotor and respiratory muscle deoxygenation during cycling exercise. Respiratory Physiology and Neurobiology, 185(3), 506\u2013514.\u00a0<a href=\"https:\/\/doi.org\/10.1016\/j.resp.2012.11.018\">https:\/\/doi.org\/10.1016\/j.resp.2012.11.018<\/a><\/p>\n<p>White, G. E., &amp; Wells, G. D. (2015). The effect of on-hill active recovery performed between runs on blood lactate concentration and fatigue in alpine ski racers. The Journal of Strength &amp; Conditioning Research, 29(3), 800-806.<\/p>\n<p>White, A. T., &amp; Johnson, S. C. (1993). Physiological Aspects and Injury in Elite Alpine Skiers. Sports Medicine: Evaluations of Research in Exercise Science and Sports Medicine, 15(3), 170\u2013178.\u00a0<a href=\"https:\/\/doi.org\/10.2165\/00007256-199315030-00003\">https:\/\/doi.org\/10.2165\/00007256-199315030-00003<\/a><\/p>\n<\/div>\n<\/div>\n<\/section>\n","protected":false},"excerpt":{"rendered":"<p>Vol. 3 N\u00fam. 2 (2021): Journal of physical education and human movement, Art\u00edculos, P\u00e1ginas 7-16 DOI:\u00a0https:\/\/doi.org\/10.24310\/JPEHMjpehmjpehm.v3i213035 \u00a0Derechos de autor\u00a0\u00a0C\u00f3mo citar Resumen El siguiente estudio analiz\u00f3 la fiabilidad de un nuevo dispositivo (Humon Beta, Dynometrics, Inc. Boston), de onda continua (continuous wave, CW), evaluando la Sm02 del vasto lateral dominante durante cuatro estadios (basal, calentamiento, ejercicio, [&hellip;]<\/p>\n","protected":false},"author":1,"featured_media":153,"comment_status":"open","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"footnotes":""},"categories":[1],"tags":[],"_links":{"self":[{"href":"https:\/\/jpehm.org\/index.php\/wp-json\/wp\/v2\/posts\/152"}],"collection":[{"href":"https:\/\/jpehm.org\/index.php\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/jpehm.org\/index.php\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/jpehm.org\/index.php\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/jpehm.org\/index.php\/wp-json\/wp\/v2\/comments?post=152"}],"version-history":[{"count":1,"href":"https:\/\/jpehm.org\/index.php\/wp-json\/wp\/v2\/posts\/152\/revisions"}],"predecessor-version":[{"id":154,"href":"https:\/\/jpehm.org\/index.php\/wp-json\/wp\/v2\/posts\/152\/revisions\/154"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/jpehm.org\/index.php\/wp-json\/wp\/v2\/media\/153"}],"wp:attachment":[{"href":"https:\/\/jpehm.org\/index.php\/wp-json\/wp\/v2\/media?parent=152"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/jpehm.org\/index.php\/wp-json\/wp\/v2\/categories?post=152"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/jpehm.org\/index.php\/wp-json\/wp\/v2\/tags?post=152"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}